INFAB Foundation Isolation
|
In some applications, it is not feasible to mount a machine directly on vibration isolators. An integral part of most machine tool installations is a properly designed foundation which will meet the machine's support requirements. Isolating a vibration-sensitive or vibration-producing machine requires isolation of its support mass or foundation.
INFAB elastomeric (rubber) isolators provide low frequency isolation from induced shock and vibration for applications requiring support foundations and inertia blocks. INFAB isolation systems can be designed to have a natural frequency as low as 6.0 Hz.
|
 |
 |
A vibration site survey/analysis will determine the levels of vibration existing at your site, which is essential for proper vibration control recommendations to be made. Please contact Fabreeka's® Engineering Department for assistance with your particular application or if you would like information regarding a vibration site survey.
|
Some features and benefits of INFAB foundation isolation:
- Standard INFAB isolators are available in load ranges from 1,800 lbs to 4,400 lbs per isolator
- Dynamically tested for natural frequency and damping data
- Natural frequency as low as 6.0 Hz
- Compatible with a variety of foundation structural support designs to meet project requirements
- Alternative isolator characteristics and complete system designs available
- Extensive database and history of installations and system designs
|
 |
 Click photo to enlarge. Test data measured on an INFAB 1T isolation system. |
Standard INFAB isolators are manufactured in the following sizes and load ranges:
 Type |
 Size (L x W x H) |
 Load (Max.) Lbs [kg] |
 Natural Frequency (Hz) |
 Damping (% Critical) |
INFAB 1T |
6" x 6" x 3.75" |
1,800 [ 810] |
7.0 |
6% |
INFAB 2T |
6" x 6" x 3.75" |
3,100 [1,400] |
7.0 |
6% |
|
|
For applications requiring an alternative to the standard INFAB isolator sizes and characteristics, INFAB isolation panels can be designed to have natural frequencies from 6.0 Hz to 10.0 Hz (6% damping) by custom designing the physical size and thickness of the isolators. The panels are comprised of rubber INFAB isolators secured to a rigid substrate, which is used as the forming for the bottom of the concrete foundation. The panel feature allows for greater flexibility in the structural support design of the foundation and a less costly installation.
Please contact Fabreeka's® Engineering Department for assistance with your foundation isolation application.
Some typical INFAB applications include:
- Dynamometers
- Precision Machine Tools
- Floating Floors
- Coordinate Measuring Machines
- Anechoic Chambers
- Roller Mills
- Pulp & Paper Machinery
- Presses
- Printing Presses
- Looms
|
 |

 |
Please contact Fabreeka® to request a brochure.